Product
Data
Section 7: Sheet 24 |
Okonite® - Communication Cable
for Transit Systems
Duct and
Tunnel Installations for Transit Systems
Low Smoke, Zero Halogen,
Thermoplastic Jacket
|
A Solid Bare Copper Conductor
B Color Coded Thermoplastic
Insulation
C Non-Hydroscopic Core Tape
D .005” Copper Shield
E Okoclear-TP Jacket
Construction
Conductors: 16, 19, and 22 AWG solid, soft bare copper wires.
Insulation: A thermoplastic compound, color coded per telephone industry
standards.
Core Assembly: Insulated conductors are twisted into pairs with varying
lengths of lay to minimize cross-talk. Pairs are oscillated into cable
or units with identifying non-hygroscopic binders. Concentric/oscillated
construction through 25 pairs and unit construction for larger cables. A
non-hygroscopic core tape is applied over the cable core as a dielectric
and heat barrier.
Shield: A .005” copper tape is longitudinally applied with an overlap
and corrugated to increase flexibility.
Jacket: The black jacket is
resistant to abrasion, moisture, weather and environmental cracking. It
meets the requirements of ICEA S-73-532. The jacket is surface printed
with year of manufacture, product description and sequential footage
marks at two foot intervals.
Applications
Low smoke, zero halogenated Okonite Communication Cables for transit systems
are designed for use in aerial and tunnel installations where these features
are desired. They are ideally suited for transit communications systems.
Specifications
Manufactured to ICEA S-56-434.
Product Features
-
Color coded to telephone industry requirements.
-
Excellent mechanical and electrical characteristics.
-
100% shielding.
-
Highly resistant to abrasion, moisture, weather and environmental
cracking.
-
Low Smoke, non-halogentated construction.
|
|
Electrical Characteristics
|
|
22
AWG
|
19
AWG
|
16
AWG
|
|
Conductor Resistance — ohms/mile 68°F
|
nominal
maximum
|
85.5
92.0
|
42.5
46.0
|
21
23
|
|
Conductor Resistance — ohms/loop mile
|
nominal
maximum
|
171
184
|
85
92
|
42
46
|
|
Insulation Resistance — megohm miles
|
minimum
|
10,000
|
10,000
|
10,000
|
|
Dielectric Strength — Insulation capable of
withstanding for 3 seconds dc
voltage
— between conductors
— between conductors and shield
|
|
3,600
10,000
|
4,500
10,000
|
6,000
1,000
|
|
Attenuation at 1000 Hz-db/loop mile
|
|
1.79
|
1.25
|
0.91
|
|
Average Mutual Capacitance
mf/mile at 1000 Hz
|
Pairs
6 thru 17
18 and over
|
.083 ± 0.007
.083 ± 0.004
|
|
Capacitance Unbalance —pf/1000 ft.
Pair to Pair — R.M.S.
Maximum (individual)
|
12 or more
Less than 12
|
25
100
|
25
100
|
25
100
|
|
Pair to Shield — R.M.S.
Maximum (individual)
|
12 or more
Less than 12
|
125
250
|
125
250
|
125
250
|
|
Crosstalk Loss R.M.S. far end loss
measured at 150 KHz
|
6 or more
|
not less than 73 db per 1,000 ft.
|
|
|
|
Okonite Type RTC
|
1-Catalog Number
2-Size AWG
3-No. of Pairs
4-Jacket Thickness-mils
5-Cable O.D. - Inches |
6-Cable O.D. - mm
7-Net Wt Lbs./M’
8-Ship. Wt. Lbs./M’
9-Strand. Reel Length
10-Jumbo Reel Length |
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
|
207-82-6502
207-82-6503
207-82-6504
|
22
|
6
12
18
|
60
60
60
|
0.42
0.50
0.56
|
10.7
12.7
14.2
|
91
135
176
|
108
152
200
|
5000
5000
5000
|
10000
10000
10000
|
|
207-82-6505
207-82-6507
207-82-6508
|
25
50
75
|
60
60
60
|
0.63
0.80
0.97
|
16.0
20.3
24.6
|
221
376
541
|
245
416
632
|
5000
5000
5000
|
10000
10000
10000
|
|
207-82-6509
207-82-6511
207-82-6513
|
100
150
200
|
60
70
80
|
1.09
1.30
1.48
|
27.7
33.0
37.6
|
702
986
1282
|
793
1125
1477
|
5000
2500
2500
|
10000
5000
5000
|
|
207-82-6514
|
300
|
90
|
1.79
|
45.5
|
19053
|
2180
|
2500
|
3000
|
|
207-82-6522
207-82-6523
207-82-6524
|
19
|
6
12
18
|
60
60
60
|
0.51
0.62
0.72
|
13.0
15.7
18.3
|
136
211
286
|
153
235
325
|
5000
5000
5000
|
10000
10000
10000
|
|
207-82-6525
207-82-6527
207-82-6528
|
25
50
75
|
60
70
70
|
0.81
1.12
1.31
|
20.6
28.4
33.3
|
369
687
981
|
424
779
1120
|
5000
5000
2500
|
10000
10000
5000
|
|
207-82-6529
207-82-6531
207-82-6533
|
100
150
200
|
80
90
90
|
1.50
1.86
2.07
|
38.1
47.2
52.6
|
1256
1858
2391
|
1433
2123
2806
|
2500
1250
1250
|
5000
2500
2000
|
|
207-82-6534
|
300
|
100
|
2.47
|
72.7
|
3493
|
4023
|
1250
|
—
|
|
207-82-6542
207-82-6543
207-82-6544
|
16
|
6
12
18
|
60
60
60
|
0.62
0.80
0.97
|
15.9
20.5
24.8
|
217
363
516
|
244
406
568
|
2500
2500
2500
|
5000
5000
5000
|
|
207-82-6545
207-82-6547
207-82-6548
|
25
50
75
|
70
75
80
|
1.12
1.49
1.96
|
28.6
38.0
49.8
|
689
1252
1857
|
767
1378
2167
|
2500
2500
1000
|
5000
—
—
|
|
207-82-6549
207-82-6551
207-82-6553
|
100
150
200
|
80
90
100
|
2.04
2.45
2.79
|
51.8
62.2
70.9
|
2356
3438
4512
|
2666
3963
5158
|
1000
1000
1000
|
—
—
—
|
| |
Notes: RTC cables are available, on special order, with a T-Screen®
or core separated construction for use with PCM type carrier. To order T-Screen construction, change first five digits of catalog number
from 704-03 to 704-33. In addition to "T-Screen" and "Jelly Filled" types
these cables are available pressurized, and in "Air Core" and
"Foam" constructions.
|
|