Okotherm® CIC SP-OS Fire Resistant Cable

600V Instrumentation Cable—Aluminum Sheath Type MC
Shielded Multiple Pair or Triad
Tin or Nickel Coated Copper Conductors
90°C Wet or Dry Rating
UL 


A
  Nickel or Tin Coated Copper Conductors

B  Okotherm (Silicone) Thermoset Insulation

C  Fiberglass Braid - Coded per ICEA

D  Twisted, Shielded Pairs/Triads

E  Nickel or Tin Coated Copper Drain Wire

F  Fiberglass Fillers, as needed

G Aluminum-Mylar Shield Tape

H Flame Retardant Binder Tape

J Impervious, Continuous, Corrugated, Aluminum C-L-X Sheath

K Black Okoseal Jacket



Cable Description
Tin or nickel coated copper conductors, Okotherm CIC fire resistant thermoset silicone insulation, color or number coded fiber glass braid, cabled conductors, tin or nickel coated drain wire, aluminum-polyester shield tape, fire resistant cable tape, aluminum CLX sheath, Okoseal (PVC) jacket.

Conductors: Tin or nickel coated copper

Insulation: Okotherm Thermoset Silicone

Braid: Fiber Glass Braid

Color Code: ICEA S-73-532, Method 7

Group Shield: Aluminum polyester tape overlapped to provide 100% coverage, and a 7-strand tin or nickel coated copper drain wire, two sizes smaller than the conductor. All group shields are completely isolated from each other.

Assembly: Pairs or triads assembled with left hand lay. Fiberglass fillers included where required to provide a round cable.

Cable Shield: Aluminum/polyester tape over- lapped to provide 100% coverage and a 7-strand tin or nickel coated copper drain wire, same size as conductors.

Armor-CLX: Continuously Welded and Corrugated Aluminum

Outer Jacket: Black PVC

Applicable Industry Standards:
— UL 1569, 1309, & 2250 — ICEA S-73-532 (NEMA WC 57) — ASTM B-33 & B-355

Flame Tests: IEC 60331, ICEA T-29-520, IEEE 1202

Applications
Okotherm CIC 600 volt instrumentation cables are used in systems where, in the event of a fire, circuit integrity is required in order to maintain a process or to safely shut down the process. Fire resistance is determined by compliance to the IEC 60331 circuit integrity fire test. Okotherm CIC nickel coated copper cables maintain circuit integrity based on qualification to the IEC standard 60331 for all temperatures and times up to and including 1000°C for three hours. When exposed to a fire, the Okotherm CIC insulation becomes an electrically insulating ceramic-like ash that is capable of maintaining the operating voltage.
Okotherm CIC CLX Type MC cables with the impervious, continuous aluminum corrugated sheath are recommended as an alternative to a wire conduit system. These cables may be installed indoors or outdoors, in wet or dry locations, as open runs of cable secured to supports not more than six feet apart, in cable tray, as an aerial cable on a messenger, in any approved raceway, direct burial, or encased in concrete. They are also approved for use in Class I & II, Division 2, Class III, Division 1 and 2 and Class I, Zones 1 & 2 hazardous locations per NEC Articles 501, 502, 503, and 505. They are listed by the American Bureau of Shipping (ABS) as CWCMC-CLXM and by UL as marine shipboard cable. The isolated individual shields over each pair, when properly grounded, prevent crosstalk or capacitive coupling between adjacent pairs which occurs with ac signals, particularly the pulse type. The overall shield eliminates most of the static interference from the electric field radiated by power cables and other electrical equipment.
Okotherm CIC 600 volt instrumentation cables should be considered on circuits designed for fire detection and suppression, alarms, communication, circuits requiring redundancy and personnel egress.

Product Features

  • UL Listed as Type MC cable and Marine Shipboard Cable, E38916 and E137931.
  • UL Listed for cable tray use, direct burial and sunlight resistant.
  • Passes the IEEE 383-1974 and IEEE 1202 vertical tray flame tests.
  • Passes the 210,000 BTU ICEA T-29-520 Vertical Tray Flame Test.
  • Complete pre-packaged, factory-tested wiring system.
  • Individual pairs or triads are numbered and color coded for simplified hook-up.
  • C-L-X cables are quality control inspected to meet or exceed applicable UL standards.
  • 90°C continuous operating temperature in all types of installations.
  • 130°C emergency rating.
  • 250°C short circuit rating.
  • Good EMI shielding characteristics.
  • Individual units are completely isolated for maximum noise rejection.
  • Impervious, continuous metallic sheath excludes moisture, gases and liquids.
  • Reduced sealing fitting requirements in Class I, Division 2 or Zone 2 hazardous locations (NEC Section 501.5(E) or 505.15(C).
  • Lower installed system cost than conduit or EMT systems.
  • Provides excellent grounding safety.
  • Excellent compression and impact resistance.
  • Continuous long lengths.
  • Minimum installation temperature of -40°C or °F.
  • American Bureau of Shipping listed as CWCMC Type MC.
  • Conforms to applicable requirements of IEEE 1580.


Okotherm Insulation: 45 mils
1-Catalog Number
2-Conductor Size (AWG)
3-Number of Pairs
4-Number of Triads
5-C-L-X O.D. - inches
6-C-L-X O.D. - mm
  7-Jacket Thickness-mils
  8-Nominal Cable O.D. - inches
  9-Nominal Cable O.D. - mm
10-Cross-Sectional Area (sq in)
11-Approx Net Weight (lbs/1000’)
12-Approx Ship Weight (lbs/1000’)

Tin Coated Copper Conductors, IEC Rating: 750°C for 90 minutes 

1 2 3 4 5 6 7 8 9 10 11 12

567-18-3302
567-18-3304
567-18-3308

18(7X)

2
4
8


 

0.89
0.89
1.11

22.6
22.6
28.2

50
50
50

1.00
1.00
1.22

25.4
25.4
31.0

0.79
0.79
1.17

271
348
564

351
438
654

567-18-3312
567-18-3316
567-18-3324
567-18-3336

12
16
24
36

 

1.34
1.51
1.78
2.45

34.0
38.4
45.2
62.2

50
60
60
75

1.45
1.65
1.91
2.61

36.8
41.9
48.5
66.3

1.65
2.14
2.87
5.35

769
997
1422
2217

912
1140
1609
2602

567-18-3704
567-18-3708
567-18-3712

 

4
8
12

1.06
1.37
1.64

26.9
34.8
41.7

50
50
60

1.17
1.48
1.78

29.7
37.6
45.2

1.08
1.72
2.49

465
757
1076

545
900
1240

567-18-3716
567-18-3724

 

16
24

1.87
2.32

47.5
58.9

60
75

2.00
2.48

50.8
63.0

3.14
4.83

1405
2113

1661
2498

567-18-3402
567-18-3404
567-18-3408

16(7X)

2
4
8

 

0.93
0.93
1.24

23.6
23.6
31.5

50
50
50

1.04
1.04
1.35

26.4
26.4
34.3

0.85
0.85
1.43

306
404
682

386
484
772

567-18-3412
567-18-3416
567-18-3424
567-18-3436

12
16
24
36

 

1.47
1.74
2.06
2.62

37.3
44.2
52.3
66.5

50
60
60
75

1.48
1.87
2.19
2.79

40.1
47.5
55.6
70.9

1.96
2.75
3.77
6.11

933
1277
1815
2673

1076
1464
2107
3063

567-18-3804
567-18-3808
567-18-3812

 

4
8
12

1.15
1.47
1.78

29.2
37.3
45.2

50
50
60

1.26
1.58
1.91

32.0
40.1
48.5

1.25
1.96
2.87

548
903
1344

638
1046
1531

567-18-3816
567-18-3824

 

16
24

2.01
2.49

51.1
63.2

60
75

2.14
2.65

54.4
67.3

3.60
5.52

1742
2542

2027
2927

Nickel Coated Copper Conductors, IEC Rating: 1000°C for 3 hours 

1 2 3 4 5 6 7 8 9 10 11 12

567-19-3302
567-19-3304
567-19-3308

18(7X)

2
4
8

 

0.89
0.89
1.11

22.6
22.6
28.2

50
50
50

1.00
1.00
1.22

25.4
25.4
31.0

0.79
0.79
1.17

271
348
564

351
428
654

567-19-3312
567-19-3316
567-19-3324
567-19-3336

12
16
24
36

 

1.34
1.51
1.78
2.45

34.0
38.4
45.2
62.2

50
60
60
75

1.45
1.65
1.91
2.61

36.8
41.9
48.5
66.3

1.65
2.14
2.87
5.35

769
997
1422
2217

912
1140
1609
2602

567-19-3704
567-19-3708
567-19-3712

 

4
8
12

1.06
1.37
1.64

26.9
34.8
41.7

50
50
60

1.17
1.48
1.78

29.7
37.6
45.2

1.08
1.72
2.49

465
757
1076

545
900
1240

567-19-3716
567-19-3724

 

16
24

1.87
2.32

47.5
58.9

60
75

2.00
2.48

50.8
63.0

3.14
4.83

1405
2113

1661
2498

567-19-3402
567-19-3404
567-19-3408

16(7X)

2
4
8

 

0.93
0.93
1.24

23.6
23.6
31.5

50
50
50

1.04
1.04
1.35

26.4
26.4
34.3

0.85
0.85
1.43

306
404
682

386
484
772

567-19-3412
567-19-3416
567-19-3424
567-19-3436

12
16
24
36

 

1.47
1.74
2.06
2.62

37.3
44.2
52.3
66.5

50
60
60
75

1.58
1.87
2.19
2.79

40.1
47.5
55.6
70.9

1.96
2.75
3.77
6.11

933
1277
1815
2673

1076
1464
2107
3063

567-19-3804
567-19-3808
567-19-3812

 

4
8
12

1.15
1.47
1.78

29.2
37.3
45.2

50
50
60

1.26
1.58
1.91

32.0
40.1
48.5

1.25
1.96
2.87

548
903
1344

638
1046
1531

567-19-3816
567-19-3824

 

16
24

2.01
2.49

51.1
63.2

60
75

2.14
2.65

54.4
67.3

3.60
5.52

1742
2542

2027
2927

 


ELECTRICAL SPECIFICATIONS 
Per UL Standard 44 
Conductor Resistance, nominal (1 Pr)..ohms/1000 ft. @25°C 
........................................................................T.Cu...Ni. Cu 
      18 AWG........................................................... 7.05........9.39 
      16 AWG............................................................4.44........5.89 
Insulation Test Voltage (spark test)..................7500 Volts ac 
Dielectric Test Voltage..............................3000 V ac for 5 min. 
Insulation Resistance Constant @60°F minimum                     
      (natural material typical value). ... 4000 Megohms-1000 ft. 
Loop Resistance, nominal (1 Pr)..........ohms-1000 ft @ 25°C    
.................................................................................T.Cu...Ni. Cu 
     18 AWG.................................................................14.1.....18.8 
                 16 AWG...................................................................8.9.....11.8          

 

Cross-sectional area for calculation of cable tray fill in accordance with NEC Section 392.9.
 

A/06110546
BACK TO DATA SHEET INDEX

| WELCOME | WHAT'S NEW | PRODUCT OVERVIEW | PRODUCT CATALOG | EVENTS |
| SALES OFFICES | MANUFACTURING PLANTS | SERVICE CENTERS | GLOSSARY | U.S. MAP |
 | ENGINEERING TECHNICAL CENTER | SEARCH OKONITE | SURPLUS INVENTORY |
DAILY PRICES FOR COPPER, LEAD, ALUMINUM AND STEEL SHEETS

| HOMEPAGE | CONTACT US |