A Stranded Bare Copper Conductor
B Okoseal Insulation with Nylon
Jacket
C Tinned Stranded Copper Group
Drain Wire
D Double Faced
Aluminum/Synthetic Polymer Backed Tape
E Twisted, Shielded Pairs/Triads
F Double Faced
Aluminum/Synthetic Polymer Backed Tape
G Stranded Tinned Copper Drain
Wire
H Rip Cord
J Black Okoseal Jacket
Specifications
Conductors: Bare soft annealed copper, Class B, 7-strand concentric
per ASTM B-8.
Insulation: Flame-retardant Okoseal (PVC), 15 mils nominal
thickness, nylon jacket, 4 mil nominal thickness, 90°C
temperature rating, per UL Standard 1277.
Conductor Identification: Pigmented black and white in pairs;
black, white and red in triads.
Group Shield: Aluminum/Polyester tape overlapped to provide 100%
coverage, and a 7-strand tinned copper drain wire, two sizes smaller than
the conductor. All group shields are completely isolated from each other.
Assembly: Pairs or triads assembled with1 left-hand lay.
Flame-retardant, non-wicking fillers included where required to provide a
round cable.
Cable Shield: Aluminum/Polyester tape overlapped to provide 100%
coverage, and a 7-strand tinned copper drain wire, same size as conductor.
Jacket: Black, flame-retardant, low temperature Okoseal per UL
Standard 1277, 90°C temperature
rating. A rip cord is laid longitudinally under the jacket to facilitate
removal.
Classification: UL Listed as Type TC Article 340 of the National
Electrical Code.
Applications
Okonite's Type SP-OS (Shielded pairs or triads - Overall
Shield) instrumentation cables are designed for use on Class 1
Remote-Control Signaling circuits or where a 600V cable is desired, as
instrumentation, process control, or computer cable transmitting signals
at levels above 100 mili-volts in circuits where maximum noise protection
is required. Protection
from interference among groups as well as external sources is provided by
individual group shields as well as an overall cable shield. For use
indoors or outdoors; wet or dry locations; in cable trays; in raceways;
supported by a messenger wire; for direct burial; in Class I, Division 2,
Class II, Division 2 or Class III, Division 2 hazardous locations. Also
for use as non power limited fired protective signaling cable (NPLF) per
NEC Code 760. Type TC cables can be labeled Okomarine to be used in ABS
and Coast Guard approved marine applications.
Product Features
- Passes the UL 1277 and IEEE 383-1974 vertical tray flame tests.
- Passes IEEE 1202-1991 vertical tray flame test (8 pr #18 and 4 pr
#16 & larger).
- May be combined with 600 volt power and control cables in the same
tray.
- Sunlight resistant and oil resistant.
- UL listed for direct burial (2/C #16 AWG and larger).
- Individual pairs or triads are numbered and color-coded for
simplified hook-up.
- Individual pairs or triads are completely isolated.
- 100% shield coverage for reduced electromagnetic noise pick-up.
- Good external noise rejection.
- Excellent weathering characteristics.
- OSHA Acceptable.
- Flexible, easy to handle and terminate.
- May be used in approved marine applications.
- Suitable for installation at low temperatures to -40°C.
|