THE OKONITE COMPANY
Product Data
Section 5: Sheet 31

Okoseal-N® Type SP-OS
Type TC Instrumentation Cable
Multiple Shielded Pairs or Triads - Overall Shield
600 Volts - 90°C Dry/75°C Wet Rating
For Cable Tray Use
UL 

A  Stranded Bare Copper Conductor

B  Okoseal Insulation with Nylon Jacket

C  Tinned Stranded Copper Group Drain Wire

D  Double Faced Aluminum/Synthetic Polymer Backed Tape

E  Twisted, Shielded Pairs/Triads

F  Double Faced Aluminum/Synthetic Polymer Backed Tape

G  Stranded Tinned Copper Drain Wire

H  Rip Cord

J   Black Okoseal Jacket


Specifications
Conductors: Bare soft annealed copper, Class B, 7-strand concentric per ASTM B-8.

Insulation: Flame-retardant Okoseal (PVC), 15 mils nominal thickness, nylon jacket, 4 mil nominal thickness, 90°C temperature rating, per UL Standard 1277.

Conductor Identification: Pigmented black and white in pairs; black, white and red in triads.

Group Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, two sizes smaller than the conductor. All group shields are completely isolated from each other.

Assembly: Pairs or triads assembled with1 left-hand lay. Flame-retardant, non-wicking fillers included where required to provide a round cable.

Cable Shield: Aluminum/Polyester tape overlapped to provide 100% coverage, and a 7-strand tinned copper drain wire, same size as conductor.

Jacket: Black, flame-retardant, low temperature Okoseal per UL Standard 1277, 90°C temperature rating. A rip cord is laid longitudinally under the jacket to facilitate removal.

Classification: UL Listed as Type TC Article 340 of the National Electrical Code.

Applications
Okonite's Type SP-OS (Shielded pairs or triads - Overall Shield) instrumentation cables are designed for use on Class 1 Remote-Control Signaling circuits or where a 600V cable is desired, as instrumentation, process control, or computer cable transmitting signals at levels above 100 mili-volts in circuits where maximum noise protection is required. Protection
from interference among groups as well as external sources is provided by individual group shields as well as an overall cable shield. For use indoors or outdoors; wet or dry locations; in cable trays; in raceways; supported by a messenger wire; for direct burial; in Class I, Division 2, Class II, Division 2 or Class III, Division 2 hazardous locations. Also for use as non power limited fired protective signaling cable (NPLF) per NEC Code 760. Type TC cables can be labeled Okomarine to be used in ABS and Coast Guard approved marine applications.

Product Features

  • Passes the UL 1277 and IEEE 383-1974 vertical tray flame tests.
  • Passes IEEE 1202-1991 vertical tray flame test (8 pr #18 and 4 pr #16 & larger).
  • May be combined with 600 volt power and control cables in the same tray.
  • Sunlight resistant and oil resistant.
  • UL listed for direct burial (2/C #16 AWG and larger).
  • Individual pairs or triads are numbered and color-coded for simplified hook-up.
  • Individual pairs or triads are completely isolated.
  • 100% shield coverage for reduced electromagnetic noise pick-up.
  • Good external noise rejection.
  • Excellent weathering characteristics.
  • OSHA Acceptable.
  • Flexible, easy to handle and terminate.
  • May be used in approved marine applications.
  • Suitable for installation at low temperatures to -40°C.

Okoseal Insulation - 15 mils; Nylon Jacket - 4 mils
 1-Catalog Number
 2-Size AWG Strands
 3-Number of Pairs
 4-Number of Triads
 5-Jacket Thickness- (mils)
  6-Nominal Cable O.D. - (In.)
  7
-Cross-Sectional Area    (sq in)
  8-Approx Net Weight (lbs/1000’)
  9-Approx Ship Weight (lbs/1000’)
1 2 3 4 5 6 7 8 9
261-60-3304
261-60-3308

18 (7x)

4
8
  45
60
0.50
0.67
0.20
0.35
138
258
161
297

261-60-3310
261-60-3312
261-60-3316

10
12
16
  60
80
80
0.77
0.81
0.93
0.46
0.51
0.67
316
395
496
355
459
559
261-60-3320
261-60-3324
261-60-3336
261-60-3350
20
24
36
50
  80
80
80
80
1.07
1.09
1.28
1.40
0.90
0.93
1.29
1.54
597
699
974
1307
677
779
1080
1450
261-65-3304
261-65-3308
261-65-3312
  4
8
12
60
60
80
0.61
0.75
0.95
0.29
0.44
0.71
196
317
516
220
356
580
261-65-3316
261-65-3324
261-65-3336
  16
24
36
80
80
80
1.09
1.34
1.53
0.93
1.41
1.84
652
940
1319
732
1046
1462

261-60-4402
261-60-4404
261-60-4408

16 (7x)

2
4
8

 

45
60
60

0.44
0.58
0.72

0.15
0.26
0.47

114
198
337

 137
222
376

261-60-4410
261-60-4412
261-60-4416

10
12
16

 

80
80
80

0.94
0.91
1.04

0.69
0.65
0.85

452
515
650

516
579
730

261-60-4420
261-60-4424
261-60-4436
261-60-4450

20
24
36
50

 

 80
80
80
110

1.19
1.18
1.40
1.48

 1.11
1.09
1.54
1.72

787
925
1304
1866

 867
1031
1410
2053

261-65-4404
261-65-4408
261-65-4412

 

4
8
12

60
80
80

0.61
0.79
1.00

0.29
0.49
0.79

 252
478
674

 291
542
754

261-65-4416
261-65-4424
261-65-4436

16
24
36

 80
80
80

 1.12
1.50
1.71

0.99
1.77
2.30

 858
1245
1761

964
1388
1948

261-60-5504
261-60-5508

14 (7x)

4
8
60
80
0.68
0.91
0.36
0.65
272
511
311
575
261-60-5510
261-60-5512
261-60-5516
10
12
16
80
80
80
1.06
1.09
1.20
0.88
0.93
1.13
627
721
919
707
801
1025
261-60-5520
261-60-5524
261-60-5536
261-60-5550
20
24
36
50
80
80
80
110
1.34
1.48
1.67
2.02
1.41
1.72
2.19
3.20
1120
1322
1886
2681
1226
1428
2029
2973
261-65-5504
261-65-5512
4
12
60
80
0.75
1.23
0.44
1.19
351
954
390
1060
261-65-5516
261-65-5524
261-65-5536
16
24
36
80
80
110
1.36
1.69
2.00
1.45
2.24
3.14
1225
1794
2683
1331
1987
2975

Authorized Stock Item: Available from our Customer Service Centers.

  Cross-sectional area for calculation of cable tray fill in accordance with NEC Section 318-8

Length Tolerance: Cut lengths of 1000 feet or longer are subject to a tolerance of ± 10%; less than 1000 feet ±15%.


ELECTRICAL SPECIFICATIONS
Per UL Standard 1277
Conductor Resistance, maximum ohms/1000 ft.                                
......................................................@20°C.............@25°C            
18 AWG.......................................6.09..................7.04             
16 AWG ......................................4.34..................4.43             
14 AWG.......................................2.72..................2.78             
Insulation Test Voltage (spark test)                                                  
18 - 16 AWG...............................6000 VOLTS AC                 
14 AWG.......................................7500 VOLTS AC                 
Dielectric Test Voltage......................2000 Volts ac for 1 minute     
Insulation Resistance Constant @ 60°F, minimum                            
(natural material typical value)....................2000 Ohms-1000 ft.
Loop Resistance, maximum (2 conductor)................ohms-1000 ft   
.........................................................@20°C...............@25°C       
18 AWG........................................12.18..................14.08       
16 AWG..........................................8.68....................8.86       
14 AWG..........................................5.44....................5.56       
C/05030531
BACK TO DATA SHEET INDEX

| WELCOME | WHAT'S NEW | PRODUCT OVERVIEW | PRODUCT CATALOG | EVENTS |
| SALES OFFICES | MANUFACTURING PLANTS | SERVICE CENTERS | GLOSSARY | U.S. MAP |
 | ENGINEERING TECHNICAL CENTER | SEARCH OKONITE | SURPLUS INVENTORY |
DAILY PRICES FOR COPPER, LEAD, ALUMINUM AND STEEL SHEETS

| HOMEPAGE | CONTACT US |