A Solid Thermocouple Alloy
Conductor
B Okoseal Insulation
C Tinned Stranded Copper Group
Drain Wire
D Aluminum/Synthetic Polymer
Tape
E Twisted Shielded Pairs
F Communication Wire
G Aluminum/Synthetic Polymer
Tape
H Tinned Stranded Copper Group
Drain Wire
J Rip Cord
K Inner Okoseal Jacket
L Galvanized Steel served wire
Armor
M Outer Okoseal Jacket
Specifications
Conductors: Solid alloys per ANSI MC 96.1.
Insulation: Flame-retardant Okoseal®
(PVC) per UL Standard 13 and 2250, 15 mils nominal thickness, 105°C
temperature rating.
Conductor Identification: Pigmented insulation on individual
conductors, negative conductor numerically printed for group
identification.
Group Shield: Aluminum/Polyester taped overlapped to provide 100%
coverage, and a tinned copper drain wire, two sizes smaller than the
conductor. All group shields are completely isolated from each other.
Communications Wire: 22 AWG, solid 12 mils nominal flame-retardant
Okoseal insulation, 105°C temperature
rating.
Assembly: Pairs assembled with left-hand lay. Flame-retardant,
non-wicking fillers included where required to provide a round cable.
Cable Shield: Aluminum/Polyester tape overlapped to provide 100%
coverage, and a 7-strand tinned copper drain wire, same size as the
conductor.
Inner Jacket: Color-coded, flame-retardant low temperature
Okoseal per UL Standard 13 and 2250. A rip cord is laid longitudinally
under the jacket to facilitate removal.
Wire Armor: A serving of soft annealed galvanized steel wires
applied with a left-hand lay and 90% minimum coverage.
Outer Jacket: Color-coded, flame-retardant Okoseal per UL Standard
13 and 2250.
Classification: UL Listed as Type ITC/PLTC - Instrumentation Tray
Cable/Power Limited Tray Cable for use in accordance with Article 725 and
727 of the National Electrical Code.
The cables comply with UL 2250 and UL 13 for CL2 and CL3.
Applications
Okonite SWA Type SP-OS (Pair- Individual and Overall Shield)
thermocouple extension cables are designed for use as instrumentation and
process control cables in ITC non-classified or labeled circuits up to 150
volts and 5 amps (750VA) and in Class 2 or 3 Power-Limited circuits where
maximum shielding against external interference is required, as well as
shielding among groups, particularly where the cable may be subject to
abnormally high current or voltage interference; indoors or outdoors; in
wet or dry locations with a conductor operating temperatures up to 105°C;
in cable trays; in raceways; supported by a messenger wire; under raised
floors; for direct burial. Suitable Class I, Division 2, Class II,
Division 2, or Class III, Division 2 hazardous locations. Also for use as
Power-Limited fire protective signaling cable (FPL) per NEC Code 760.
Product Features
- Passes flame test for use in cable tray.
- Sunlight resistant.
- Oil resistant.
- Excellent electromagnetic shielding.
- Individual pairs are numbered and color-coded for simplified
hook-up.
- Maximum noise rejection.
- Communication wire included in each cable for voice communication
during installation or instrument calibration.
- Excellent longitudinal strength.
- OSHA Acceptable.
- Excellent cut-through resistance.
- Meets IEC/BS Specification.
- Suitable for installation at low temperature to -40°C.
|