A Bare, Annealed, Stranded Copper ConductorsB X-Olene
Insulation - Color Coded for Identification C
Marker Tape D
Non-hygroscopic Fillers, as necessary E
Binder Tape F Impervious, Continuous, Corrugated, Aluminum
C-L-X Sheath G Black Okoseal Jacket
Insulation
X-Olene® is Okonite's trade name for its chemically cross-linked polyethylene,
with high dielectric strength. Color Coding
Conductors are color coded using base colors and tracers in accordance with the Conductor Identification Table
bellow. Assembly and Coverings
The individual conductors are cabled together with non-hygroscopic fillers and a binder tape overall. The C-L-X sheath exceeds the grounding
conductor requirements of Table 250.122 of the NEC and UL 1569.
The impervious, continuous, corrugated aluminum C-L-X sheath provides
complete protection against moisture, liquids and gases and has excellent mechanical strength. For direct burial in the ground, embedment in
concrete, or for areas subjected to corrosive atmospheres, the C-L-X sheath is protected with a low temperature black Okoseal® (PVC) jacket. Applications
C-L-X Type MC cables with the impervious, continuous, corrugated aluminum sheath are recommended as an economical alternate to a wire in conduit
system. They are authorized for use on services, feeders and branch circuits
for power, lighting, control and signaling circuits in accordance with Articles
330 and 725 of the NEC. C-L-X Type MC-HL cables may be installed indoors or outdoors, in wet
or dry locations, as open runs of cable secured to supports spaced not more than six feet apart, in cable tray, as aerial cable on a
messenger, in any approved raceway, direct burial, or encased in concrete. C-L-X Type MC-HL cables are also approved for
Classes I, II, and III Division 1 and 2 and Class I, Zones 1 and 2 hazardous locations - NEC Articles 501, 502, and
503 and UL 2225. Specifications
Conductors: Bare soft annealed copper, Class B stranding per ASTM
B-8. Insulation: X-Olene per ICEA S-73-532 and UL 44, Listed UL Type XHHW-2. Conductor Identification: Base Colors and tracers. Grounding Conductor: Bare or green insulated stranded copper per ASTM B-8, Class B. Meets or exceeds requirements of NEC Table 250.122. Assembly: Per UL 1569 with binder tape overall. Sheath: Close fitting, impervious, continuous, corrugated aluminum C-L-X per UL 1569.
Exceeds grounding conductor requirements of NEC Table 250-122.Conforms to applicable requirements of IEC 502, 540, 332-3, UL 1569 and 2225. Jacket: Black Okoseal (PVC) per UL requirements for Type MC Cables.
Product Features
- UL Listed as Type MC-HL cable and Marine Shipboard Cable, E38916 and
E137931.
- UL Listed for cable tray use, direct burial and sunlight resistant.
- CSA Listed as RA90 HL as applicable.
- Passes the IEEE 383-1974 and IEEE 1202-1991 vertical tray flame tests.
- Passes the 210,000 BTU Vertical Tray Flame Test utilizing the corner configuration and the ICEA T-29-520 Vertical Tray Flame
Test.
- Complete pre-packaged, factory-tested wiring system - color coded.
- C-L-X cables are quality control inspected to meet or exceed applicable UL standards.
- 90°C continuous operating temperature in all types of installations
- 130°C emergency rating
- 250°C short circuit rating.
- Good EMI shielding characteristics.
- Impervious, continuous metallic sheath excludes moisture, gases and liquids.
- Reduced sealing fitting requirements in Class I, Division 2 hazardous locations (NEC Section 501-5(e)).
- Lower installed system cost than conduit or EMT systems.
- Provides excellent grounding safety
- Excellent compression and impact resistance.
- Continuous long lengths.
- Installation temperature of -40°C.
- Complies with NEC Articles 501, 502 and 503 for hazardous locations.
- American Bureau of Shipping listed as CWCMC Type MC-HL.
|