| Sheet |
Eff. Issue Ref.
* |
Single Conductor Cables |
| 1
1 PDF |
F |
Okoguard®-Okoseal® Type MV-90 2.4 kV Nonshielded Power Cable One Okopact® (Compact Stranded) Copper Conductor
90°C Rating Wet or Dry |
| 2
2 PDF |
G |
Okoguard®-Okolon® Type MV-90 2.4 kV Nonshielded Power Cable
One Okopact® (Compact Stranded)
Copper Conductor/90°C Rating Wet or Dry For Cable Tray Use-Sunlight Resistant |
| 3
3 PDF |
D |
Okoguard®-Okoseal® Type MV-105 5/8kV Shielded Power Cable One Okopact® (Compact Stranded) Copper Conductor/105°C
Rating
5kV-133% or 8kV-100% Insulation Level For Cable Tray Use - Sunlight Resistant |
| 4
4 PDF |
G |
Okoguard®-Okoseal® Type MV-105 5/8kV Shielded Power Cable
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating
5kV-133% or 8kV-100% Insulation Level |
| 5
5 PDF |
D |
Okoguard®-Okolon® Type MV-105 5/8kV Shielded Power
Cable One Okopact® (Compact Stranded) Copper Conductor/105°C
Rating 5kV-133% or 8kV-100% Insulation Level For Cable Tray Use-Sunlight
Resistant |
| 6
6 PDF |
D |
Okoguard®-Okobond® Type MV-105 5/8kV Okobond Shielded Power Cable
One Okopact® (Compact Stranded) Copper Conductor 105°C Rating
5kV-133% or 8kV-100% Insulation Level For Direct Burial & Conduit Use |
| 7
7 PDF |
D |
Okoguard®-Okolon® Type MV-105 8kV Shielded Power Cable
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating
100% and 133% Insulation Level For Cable Tray Use-Sunlight Resistant |
| 8
8 PDF |
G |
Okoguard®-Okoseal® Type MV-105 15kV Shielded Power Cable
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating
100% and 133% Insulation Level For Cable Tray Use-Sunlight Resistant |
| 9
9 PDF |
E |
Okoguard®-Okoseal® Type MV-105
15kV Shielded Power Cable
One Okopact® (Compact Stranded) Copper Conductor/105°C Rating
100% and 133% Insulation Level |
| 10
10 PDF |
C |
Okoguard®-Okoseal® Type MV-105 15kV Shielded Power Cable
One Aluminum Conductor/105°C Rating
100% and 133% Insulation Level |
| 11
11 PDF |
G |
Okoguard®-Okolon® Type MV-105 15kV Shielded Power Cable One Okopact® (Compact Stranded) Copper Conductor/105°C Rating
100% and 133% Insulation Level For Cable Tray Use-Sunlight Resistant |
| 12
12 PDF |
D |
Okoguard®-Okolon® Type MV-105 15kV LCS
Shielded Power Cable
One Okopact®
(Compact
Stranded) Copper Conductor/105°C Rating 100% and 133% Insulation Level For
Cable Tray Use - Sunlight Resistant |
| 13
13 PDF |
D |
Okoguard®-Okobond® Type MV-105 15kV
Okobond Shielded Power Cable
One Okopact®
(Compact
Stranded) Copper Conductor 105°C Rating 133% Insulation Level For Direct
Burial & Conduit Use |
| 14
14 PDF |
E |
Okoguard®- Okoseal® Type MV-105 25kV
Shielded Power Cable
One Okopact®
(Compact
Stranded) Copper Conductor/105°C Rating 100% and 133% Insulation Level |
| 15
15 PDF |
D |
Okoguard®-Okolene® Type MV-105 25kV
LCS Shielded Power Cable
One Aluminum
Conductor/105°C Rating 100% Insulation Level Sunlight Resistant |
| 16
16 PDF |
E |
Okoguard®-Okoseal® Type MV-105 35kV
Shielded Power Cable
One Okopact®
(Compact
Stranded) Copper Conductor/105°C Rating 100% and 133% Insulation Level |
| 17
17 PDF |
D |
Okoguard®-Okoseal® Type MV-105 35kV
Shielded Power Cable
One Aluminum
Conductor/105°C Rating 100% and 133% Insulation Level |
| 18
18 PDF |
C |
Okoguard®-Okoseal® 69kV Shielded Power
Cable
Conductor/105°C Rating — 100% Insulation Level |
|
| Sheet |
Eff. Issue Ref. |
Multi-Conductor Cables |
| 19
19 PDF |
B |
Okoguard® Okoseal® Type MV-105 5/8kV
OkoguardShielded Power Cable
3 Okopact®
(Compact
Stranded) Copper Conductors/105°C Rating 5kV-133% or 8kV-100% Insulation
Level For Cable Tray Use-Sunlight Resistant-For Direct Burial |
| 20
20 PDF |
B |
Okoguard® Okoseal® Type MV-105 15kV
OkoguardShielded Power Cable
3 Okopact®
(Compact
Stranded) Copper Conductors/105°C Rating 100% & 133% Insulation Level For
Cable Tray Use-Sunlight Resistant-For Direct Burial |
| 21
21 PDF |
H |
C-L-X®Type MV-90 or MC-HL 2.4 kV Okoguard®
Nonshielded Power Cable-Aluminum Sheath
3 Okopact®
(Compact
Stranded) Copper Conductors/90°C Rating 100% and 133% Insulation Level For
Cable Tray Use-Sunlight Resistant-For Direct Burial |
| 22
22 PDF |
E |
C-L-X®
Type MV-105 or MC-HL 5/8kV Okoguard®
Shielded Power Cable-Aluminum Sheath
3 Okopact (Compact Stranded)
Copper Conductors/105°C Rating 5kV-133% or 8kV-100% Insulation Level For
Cable Tray Use-Sunlight Resistant-For Direct Burial |
| 23
23 PDF |
E |
C-L-X® Type MV-105 or MC-HL 15kV Okoguard®
Shielded Power Cable-Aluminum Sheath
3 Okopact®
(Compact
Stranded) Copper Conductors/105°C Rating 100% Insulation Level For Cable
Tray Use-Sunlight Resistant-For Direct Burial |
| 24
24 PDF |
D |
C-L-X® Type MV-105 or MC-HL 15kV Okoguard®
Shielded Power Cable-Aluminum Sheath
3 Okopact®
(Compact
Stranded) Copper Conductors/105°C Rating 133% Insulation Level For Cable
Tray Use-Sunlight Resistant-For Direct Burial |
| 25
25 PDF |
E |
C-L-X® Type MV-105 or MC-HL 25kV Okoguard®
Shielded Power Cable-Aluminum Sheath
3 Okopact®
(Compact
Stranded) Copper Conductors/105°C Rating 100% and 133% Insulation Level For
Cable Tray Use-Sunlight Resistant-For Direct Burial |
| 26
26 PDF |
F |
C-L-X® Type MV-105 or MC-HL 35kV Okoguard®
Shielded Power Cable-Aluminum Sheath
3 Okopact®
(Compact
Stranded) Copper Conductors/105°C Rating 100% and 133% Insulation Level For
Cable Tray Use-Sunlight Resistant-For Direct Burial |
| 27
27 PDF |
C |
Loxarmor® Type MV-90 or MC 2.4kV Okoguard®
Nonshielded Power Cable
3 Okopact®
(Compact
Stranded) Copper Conductors/90°C Rating 100% and 133% Insulation Level For
Cable Tray Use-Sunlight Resistant-For Direct Burial |
| 28
28 PDF |
C |
Loxarmor®Type MV-105 or MC 15kV Okoguard®
Shielded Power Cable
3 Okopact®
(Compact
Stranded) Copper Conductors/105°C Rating 100% Insulation Level For Cable
Tray Use-Sunlight Resistant-For Direct Burial |
| 29
29 PDF |
C |
Loxarmor® Type MV-105 or MC 15kV Okoguard®
Shielded Power Cable
3 Okopact®(Compact
Stranded) Copper Conductors/105°C Rating 133% Insulation Level For Cable
Tray Use-Sunlight Resistant-For Direct Burial |
| 30
30 PDF |
C |
Okoguard® Submarine Cable 15 kV Shielded Power
Cable 3 Copper Conductors/90°C Rating 133% Insulation Level |
| Sheet |
Eff. Issue Ref. |
Paper Insulated Cable |
| 31
31 PDF |
C |
Solid Type PILC 15kV Paper Insulated Lead Covered Power
Cable Three
Copper Conductors/90°C Rating 100% Insulation Level |
| 32
32 PDF |
B |
Solid Type Bronze C-L-X® 15kV Paper Insulated
Bronze Covered Power Cable
Three Copper
Conductors/90°C Rating 100% Insulation Level |
| Sheet |
Eff. Issue Ref. |
Single Conductor Cables |
| 33
33 PDF |
B |
Solid Type PILC 15kV Paper Insulated Lead Covered Power
Cable Single
Copper Conductor/90°C Rating 100% Insulation Level |
| Sheet |
Eff. Issue Ref. |
Underground Residential Distribution
Cable |
| 34
34 PDF |
C |
Okoguard® URO 15kV Underground Primary
Distribution Cable
Aluminum
Conductor/105°C Rating 133% Insulation Level |
| 35
35 PDF |
D |
Okoguard® URO-J 15kV Underground Primary
Distribution Cable-Jacketed
Red Identification
Stripes Aluminum Conductor/105°C Rating 100% and 133% Insulation Levels |
| 36
36 PDF |
E |
Okoguard® URO-J 15kV Underground Primary
Distribution Cable-Jacketed
Red Identification
Stripes Filled Strand Aluminum Conductor/105°C Rating 100% and 133%
Insulation Levels |
| 37
37 PDF |
C |
Okoguard® 15kV Reduced Diameter Duct Cables (Triplexed)
Okopact Copper Conductor/105°C Rating 100% Insulation Level |
| 38
38 PDF |
B |
Okoguard® CIC URO-J Cable-In-Conduit 15 to 35kV
Primary Underground Distribution Cable-Full Neutral
One Aluminum
Conductor/105°C Rating — 100% and 133% Insulation Level |
| 39
39 PDF |
D |
Okoguard® URO-J 25kV Underground Primary
Distribution Cable-Jacketed
Red Identification
Stripes Aluminum Conductor/105°C Rating 100% and 133% Insulation Levels |
| 40
40 PDF |
C |
Okoguard® URO-J 35kV Underground Primary
Distribution Cable-Jacketed
Red Identification
Stripes Aluminum Conductor/105°C Rating 100% and 133% Insulation Levels |
| 41
41 PDF |
B |
Okoguard®-Okosheath-TS® Medium Voltage
Power Cable
5/8kV Shielded Power Cable One Okopact(Compact Stranded) Copper
Conductor/90°C Rating 5kV-133% or 8kV-100% Insulation Level For Class 1E
Nuclear Plant Use |
| 42
42 PDF |
C |
Okoguard® URO-J 15kV to 35kV Underground Primary
Distribution Cable Jacketed — Red Identification Stripes
Copper Conductor/105°C
Rating 100% and 133% Insulation Level |
|
|
*To
assure that a Data Sheet is the current issue, the
alphabetic index reference should agree with the
alphabetic reference on the individual data sheet.
This reference precedes the issue code numbers
located at the bottom of each sheet. |